The Fixation of Unstable Metaphyseal Distal Radius Fractures: A Randomized, Controlled Trial
In Brief
A clinical study evaluating Intramedullary Radius Fixation (Micronail) and Volar Plate Fixation for Distal Radius Fractures. Completed, enrolled 60 participants across 1 site.
Detailed Summary
Wrist fractures are the most common type of fractures that occur in the shoulder, arm, and hand. Approximately 250,000 to 300,000 wrist fractures occur in the United States each year. Although some wrist fractures can be treated using casts, many other fractures must be treated with surgery. The surgery involves using metal plates and screws to put the broken pieces of bone together so that they can heal. The purpose of this study is to compare two specific types of surgery that are used to treat broken wrists. One type uses pieces of metal that are placed on the outside of the broken pieces of bone that are screwed in place while the broken bones heal. The other type of surgery involves placing a piece of metal inside the bone marrow to hold the broken pieces of bone together as they heal. Individuals with broken wrists who participate in this study will be randomly assigned to receive one of the two types of surgical treatment. Both surgical treatments are approved and are not experimental. Study participants will be followed closely after surgery to determine the time required for them to return to their usual daily activities involving the use of their arms and hands. Although both groups of study participants are expected to experience the same outcomes at one year, those participants that receive the device placed inside the bone marrow may return to their normal functional activities earlier than the ones treated with the plate placed on the outside of the bone. Study participants and their surgeons will complete data sheets and questionnaires that will document their progress following treatment of their wrist fractures.
Study Details
Timeline
Interventions
After adequate anesthesia was obtained and the patient was prepared for surgery, distraction was applied to the fracture site and preliminary reduction of the distal radius fracture was performed under fluoroscopic guidance. A pin was inserted to maintain the fracture reduction, then the Micronail was inserted inside the radius. The metaphyseal defect created by the fracture was filled using allograft or autograft bone material. Limited incisions at either the radial or ulnar columns was performed to achieve acceptable reduction of the fracture. Radiographic parameters were used to evaluate the results of the surgical management with intramedullary nailing.
After adequate anesthesia, longitudinal traction of the wrist was applied. Based on the fracture pattern, fragments were reduced and stabilized using either one 2.4mm titanium pre-contoured locking plate or a combination of locking plates. Arthrotomy was performed to verify that the fracture fragments were reduced. Plates were contoured to fit boney contours as needed. Allograft or autograft was placed in the fracture repair site as necessary. Radiographic landmarks were evaluated. Care was taken to ensure that plates were covered with periosteum or retinaculum to reduce the incidence of possible soft tissue irritation caused by the plate on the bone. The skin incision was closed; a removable splint applied.