CI

At a glance

ClinicalIndex Comparison Record
N/ACompleted· 59 enrolled
Drug / intervention
HELIOX +3 moreother
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT00922350
NCT00922350N/ACompleted

Heliox and Posture Optimize Action of Nebulization With Bronchodilators for Asthma Attacks. Randomized Trial.

Universidade Federal de Pernambuco·interventional·Posted Jun 17, 2009·Updated Jun 17, 2009

In Brief

A clinical study evaluating HELIOX, OXYGEN, and 2 other interventions for Acute Asthma. Completed, enrolled 59 participants across 1 site.

Detailed Summary

The purpose of this study is to verify that nebulization with bronchodilators associated with heliox gas (helium + oxygen) and the posture of a leaning forward truck is effective in patients with an asthma attack.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
ConditionsAcute Asthma
CountriesBrazil
Collaborators--

Timeline

N/ACompletedFinished
20082009201020112012201320142015201620172018201920202021202220232024202520262027
First PostedJun 17, 2009
Enrollment StartJun 1, 2008
Primary CompletionDec 1, 2008
TodayJul 2, 2026
Enrollment to primary: 6 monthsPosted 17.0 years ago

Interventions

HELIOXother

The nebulization was conducted in the same way that heliox + posture group, except the attitude of trunk, where the patients in this group did the Nebulizer with the trunk upright.

OXYGENother

The NEBULIZATION was performed the same way as the heliox group, except for torso posture, where the patients in this group with the trunk upright Nebulizer Oxygen for cars have A NEBULIZATION.

HELIOX+POSTUREother

Patients underwent two carried by heliox nebulization associated with fenoterol (2.5 mg) and ipratropium bromide (0.25 mg). We used three ml of saline solution at 0.9%. For nebulization with heliox or oxygen, was used a system of distribution not invasive, semi-closed in a mask that is non toxic connected to a piece "Y" with a nebulizer in a follow and a bag of tank with a capacity for 2.5 L in the other connected with a valve action. This system was used so that there was a dilution gas. The proportion of 80:20 heliox was used (80% helium: 20% oxygen). To postural change in groups and heliox Oxygen + posture + posture, oriented to the participants to maintain an angle of inclination of the trunk and elbows supported on the thighs, measured from the anterior axillary line and lateral epicondyle of the femur, between 50th and 60th .

OXYGEN + POSTUREother

The NEBULIZATION was conducted in the same way that heliox + posture GROUP, however the patients in this group have the Oxygen for Carr A NEBULIZATION