CI

At a glance

ClinicalIndex Comparison Record
Phase 2Completed· 100 enrolled
Drug / intervention
needledevice
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT01218243
NCT01218243Phase 2Completed

An Efficacy Trial of Electroacupuncture at Points of Bilateral BL33 for Mild and Moderate Benign Prostatic Hyperplasia

Guang'anmen Hospital of China Academy of Chinese Medical Sciences·interventional·Posted Oct 11, 2010·Updated May 27, 2013

In Brief

A Phase 2 clinical trial evaluating needle for Benign Prostatic Hyperplasia (BPH). Completed, enrolled 100 participants across 1 site.

Detailed Summary

To evaluate efficacy of BL33 for mild and moderate benign prostatic hyperplasia(BPH).There are trials showing that electroacupuncture on BL33 for mild and moderate BPH is more effective than terazosin. It could reduce the International Prostate Syndrome Score (IPSS) by 6.68±2.84(39.79%),lower urinary symptoms bother of score(BS) and bladder residual urine, and increase maximum urinary flow rate.But the efficacy of BL33 has not been studied. The objective of this study is to evaluate efficacy of BL32 for mild and moderate BPH by comparison with non-acupoint group.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesChina
Collaborators--

Timeline

Phase 2CompletedFinished
2011201220132014201520162017201820192020202120222023202420252026
First PostedOct 11, 2010
Enrollment StartSep 1, 2010
Primary CompletionMar 1, 2012
Study CompletionMay 1, 2012
TodayJul 2, 2026
Enrollment to primary: 1.5 yearsPosted 15.7 years ago

Interventions

needledevice

For the acupoint group,needle on bilateral BL33 60-80mm with a 45°angle. A feeling of soreness and distension will be felt when needling into the 3rd posterior sacral foramina(S3).Needle with a 100-125 mm long needle without lifting, thrusting or rotating.An electric stimulator is put on.G6805-2 electric stimulator (produced by Shanghai Huayi Medical Instrument Co.Ltd), Sparse-dense wave,20Hz. Stop turning up the current intensity when patients could not stand. 5 times for the first two weeks and 3 times for the last two weeks, 30 min/time.The non-point group take the place 2 cun far from BL33 on the outside horizontally as the non-point and the manipulation methods are the same with those of the point group.