CI

At a glance

ClinicalIndex Comparison Record
Phase 4Completed· 84 enrolled
Drug / intervention
Kyphon® Balloon Kyphoplasty (Kyphon Inc; Sunnydale, CA)device
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT01383616
NCT01383616Phase 4Completed

Unipedicular vs. Bipedicular Kyphoplasty for the Treatment of Osteoporotic Vertebral Fractures

Hospital for Special Surgery, New York·interventional·Posted Jun 28, 2011·Updated Jul 2, 2017

In Brief

A Phase 4 clinical trial evaluating Kyphon® Balloon Kyphoplasty (Kyphon Inc; Sunnydale, CA) for Vertebral Compression Fracture. Completed, enrolled 84 participants across 1 site.

Detailed Summary

Balloon kyphoplasty for the treatment of patients with osteoporotic vertebral compression fractures has been shown to be successful in providing acute pain relief, enabling improved function, and restoring of vertebral body height. However, limited prospective data exists in the investigation of unipedicular balloon kyphoplasty as a sufficient alternative to bipedicular balloon kyphoplasty. The purpose of this prospective randomized study was to compare the clinical and radiographic outcomes of unipedicular and bipedicular balloon kyphoplasty.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesUnited States
Collaborators--

Timeline

Phase 4CompletedFinished
2006200720082009201020112012201320142015201620172018201920202021202220232024202520262027
First PostedJun 28, 2011
Enrollment StartJul 1, 2006
Primary CompletionDec 1, 2012
TodayJul 2, 2026
Enrollment to primary: 6.4 yearsPosted 15.0 years ago

Interventions

Kyphon® Balloon Kyphoplasty (Kyphon Inc; Sunnydale, CA)device

A Jamshidi Crown Bone Biopsy Needle (Cardinal Health; Dublin, OH) was then introduced through the incision into the pedicle, and advanced through the pedicle into the center of the vertebral body using a mallet at a 30 to 45 degree angle relative to the AP axis. A guidewire was then placed through the Jamshidi needle, and the needle removed. A series of dilating cannulae were then advanced over the guidewire until a working cannula was in place. A 15 millimeter (mm) or 20 mm bone tamp (Kyphon Inc; Sunnydale, CA) was then introduced into the vertebral body via the cannula and inflated until the balloon was in contact with the subchondral plate, lateral vertebral body wall, or anterior cortex of the vertebral body. The balloon was then deflated and removed. Subsequently, cement was injected into the cavity and allowed to harden.