CI

At a glance

ClinicalIndex Comparison Record
N/ACompleted· 2,008 enrolled
Drug / intervention
Absorb BVS +1 moredevice
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT01751906
NCT01751906N/ACompleted

A Clinical Evaluation of Absorb™ BVS, the Everolimus Eluting Bioresorbable Vascular Scaffold in the Treatment of Subjects With de Novo Native Coronary Artery Lesions.

Abbott Medical Devices·interventional·Posted Dec 18, 2012·Updated Oct 11, 2023

In Brief

A clinical study evaluating Absorb BVS and XIENCE for Coronary Artery Disease and 3 related conditions. Completed, enrolled 2,008 participants across 192 sites in 2 countries.

Detailed Summary

The ABSORB III RCT is a prospective randomized, single-blind, multi-center trial. It is the pivotal trial to support the US pre-market approval (PMA) of Absorb™ Bioresorbable Vascular Scaffold (BVS). The ABSORB III includes additional two trials i.e. ABSORB III PK (pharmacokinetics) sub-study and ABSORB IV RCT trial which are maintained under one protocol because both trial designs are related, ABSORB IV is the continuation of ABSORB III and the data from ABSORB III and ABSORB IV will be pooled to support the ABSORB IV primary endpoint. Both the trials will evaluate the safety and effectiveness of Absorb BVS.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesAustralia, United States
Collaborators--

Timeline

N/ACompletedFinished
20132014201520162017201820192020202120222023202420252026
First PostedDec 18, 2012
Enrollment StartDec 1, 2012
Primary CompletionSep 1, 2016
Study CompletionOct 1, 2020
TodayJul 2, 2026
Enrollment to primary: 3.8 yearsPosted 13.5 years ago

Interventions

Absorb BVSdevice

* Scaffold diameters: 2.5, 3.0 and 3.5 mm * Scaffold lengths: 8, 12, 18, and 28 mm The 3.0 x 18 mm Absorb BVS will be used for the Lead-In. Both the 8 mm and 12 mm lengths will be available for the 2.5/3.0 mm diameter Absorb BVS. Only the 12 mm length will be available for the 3.5 mm diameter. * The commercially approved CE marked device will be used in geographies where it is commercially available. The commercially approved CE marked 23mm Absorb BVS device will not be used in this study. Bioabsorbable drug eluting stent implantation for improving coronary luminal diameter in patients, including those with diabetes mellitus, with ischemic heart disease due to de novo native coronary artery lesions (length ≤ 24 mm) with a reference vessel diameter of ≥ 2.5 mm and ≤ 3.75 mm.

XIENCEdevice

Commercially approved XIENCE Family Stent System, inclusive of XIENCE V, XIENCE PRIME, XIENCE Xpedition, XIENCE Alpine, XIENCE Pro (OUS only), and XIENCE ProX (OUS only). * Stent diameters: 2.5, 2.75, 3.0, 3.25, 3.5 and 4.0 mm * Stent lengths: 8, 12, 15, 18, 23, and 28 mm. The 3.25 mm is only available for XIENCE Xpedition * For geographies where these devices are commercially available, the investigational sties may use only their locally approved devices To improve coronary luminal diameter in patients, including those with diabetes mellitus, with ischemic heart disease due to de novo native coronary artery lesions (length ≤ 24 mm) with a reference vessel diameter of ≥ 2.5 mm and ≤ 3.75 mm.