NCT01801241N/ACompleted

Comparison of Glenoid Component Position Using Intelligent Reusable Instrument (IRI) vs Standard Surgical Instruments

The Cleveland Clinic·interventional·Posted Feb 28, 2013·Updated Nov 3, 2021

In Brief

A clinical study evaluating Anatomic TSA using IRI Instrumentation and Anatomic Total Shoulder Arthroplasty for Anatomic Total Shoulder Arthroplasty. Completed, enrolled 56 participants across 1 site.

Detailed Summary

The proposed clinical study will enroll patients indicated for standard of care anatomic total shoulder arthroplasty. They will receive all pre operative testing, intra-operative care including all implants and post operative care that is standard of care and specific to the surgeon and patients decisions for care. The only difference between the study groups will be the type of surgical instruments used to place the glenoid guide pin. In all cases the surgeon is able and allowed to use their own surgical judgment to place the guide pin, prepare the bone and place the desired implant. In cases that are randomized to the IRIS group the surgeon can use any and all of the standard instruments or guides provided by the implant manufacturer as the surgeon would use in the group of patients randomized to the standard surgical group. If the surgeon chooses not to use the IRIS instruments then this would be noted as a deviation in plan, the reasons recorded and the patient would be excluded from the study without post operative imaging and there pre - operative and intra - operative data would be analyzed for the purpose of understanding the reasons for failure of the IRIS technology to provide surgical assistance for guide pin placement. For patients included in the post operative data analysis will a study specific shoulder CT scan prior to discharge from the hospital to assess the position of the implant. Deviation in the location and position of the implant as compared plan will be our primary outcome measure. Investigators will compare difference between technologies, differences within and between surgeons and the influence of the severity of the pre operative pathology on the two methods of surgical care.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesUnited States
Collaborators--

Timeline

N/ACompletedFinished
20132014201520162017201820192020202120222023202420252026
First PostedFeb 28, 2013
Enrollment StartJan 1, 2013
Primary CompletionDec 1, 2013
TodayJul 2, 2026
Enrollment to primary: 11 monthsPosted 13.3 years ago

Interventions

Anatomic TSA using IRI Instrumentationdevice

Anatomic Total Shoulder Arthroplasty (TSA) will be performed using the SmartBone and Intelligent Reusable Instrument (IRI) to transfer the pre-operative plan for glenoid implant positioning to the patient's anatomy.

Anatomic Total Shoulder Arthroplastyprocedure

Anatomic Total Shoulder Arthroplasty will be performed by the two surgeons of the study as their Standard of Care. All procedures associated with the surgery will be the same in the two arms, with the exception of the tools used to place the guide pin for placement of the glenoid implant.