CI

At a glance

ClinicalIndex Comparison Record
N/ACompleted· 58 enrolled
Drug / intervention
Tracheal Intubation using I-gel and ventilating bougie +1 moredevice
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT02566135
NCT02566135N/ACompleted

I-gel Versus C-LMA as a Conduit for Tracheal Intubation Using Ventilating Bougie

Medical College Baroda·interventional·Posted Oct 2, 2015·Updated Jul 27, 2018

In Brief

A clinical study evaluating Tracheal Intubation using I-gel and ventilating bougie and Tracheal Intubation using C-LMA and ventilating bougie for Intubation; Difficult. Completed, enrolled 58 participants.

Detailed Summary

Supraglottic Airway devices(SGAs) like I-Gel and C-LMA ( classic laryngeal mask airway ) have been used as a conduit for tracheal intubation using ventilating bougie. General Anaesthesia with tracheal intubation is one of the technique for giving anaesthesia. Tracheal intubation may become difficult sometimes and endangers patients life. Using SGAs as a conduit for tracheal intubation helps in securing airway. This will be further facilitated by using ventilating bougie, as it maintains oxygenation.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
Countries--
Collaborators--

Timeline

N/ACompletedFinished
2014201520162017201820192020202120222023202420252026
First PostedOct 2, 2015
Enrollment StartMar 1, 2014
Primary CompletionJan 1, 2015
Study CompletionFeb 1, 2015
TodayJul 2, 2026
Enrollment to primary: 10 monthsPosted 10.8 years ago

Interventions

Tracheal Intubation using I-gel and ventilating bougiedevice

Following general anaesthesia I-gel was inserted. After proper placement . ventilating bougie was inserted. Once it's placement is confirmed I-gel was removed keeping the ventilating bougie in situ. Then appropriate sized endotracheal tube was railroaded over ventilating bougie then it (v.bouggie) was removed . Proper placement of endotracheal tube was confirmed by bilateral equal chest excursion and air entry on auscultation, absence of gastric insuffflation sound over epigastrium and 'sine' wave on capnography. Maximum 3 attempts were allowed for I-gel, ventilating bougie and endotracheal tube.

Tracheal Intubation using C-LMA and ventilating bougiedevice

Following general anaesthesia C-LMA was inserted. After proper placement of C-LMA, ventilating bougie was inserted. It's placement was confirmed and C-LMA was removed after deflation of cuff keeping the ventilating bougie in situ. Then appropriate sized endotracheal tube was railroaded over ventilating bougie. It's placement was confirmed by bilateral equal air entry and chest excursion, absence of gastric insufflation sound over epigastrium and 'sine' wave on capnography. Maximum 3 attempts were allowed for C-LMA , ventilating bougie and endotracheal tube.