The Effectiveness of Alternating Ventral Intermediate Nucleus Deep Brain Stimulation Parameters in Preventing Tolerance in Essential Tremor Patients

Oregon Health and Science University·interventional·Posted Oct 28, 2016·Updated Sep 21, 2018

In Brief

A clinical study evaluating Alternating stimulation and Placebo for Essential Tremor and Deep Brain Stimulation. Completed, enrolled 22 participants across 1 site.

Detailed Summary

The purpose of this study is to investigate the hypothesis that alternating DBS parameters on a weekly basis will prevent tolerance to stimulation and thus waning of benefit, compared with non-alternating stimulation. The primary endpoint will be preserved tremor control with the alternating group compared with standard treatment using the Tremor Research Group Essential Tremor Rating Assessment Scale (TETRAS). Key secondary endpoints will be preserved activities of daily living measures as well as preserved tremor control as quantified by motion sensor data. This study has one primary aim: To determine if alternating DBS stimulation parameters on a weekly basis will be superior at preserving tremor control compared with usual stimulation (non-alternating stimulation) in ET patients with VIM DBS.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesUnited States
Collaborators--

Timeline

N/ACompletedFinished
2017201820192020202120222023202420252026
First PostedOct 28, 2016
Enrollment StartOct 1, 2016
Primary CompletionJun 1, 2017
Study CompletionJul 1, 2017
TodayJul 2, 2026
Enrollment to primary: 8 monthsPosted 9.7 years ago

Interventions

Alternating stimulationother

Two different, but equally efficacious, settings will be determined for each subject. The settings will differ by a minimum of two of the following parameters: electrode configuration, voltage, frequency and pulse width. The different settings will be named Setting A and Setting B. The treatment cohort will receive both Setting A and Setting B that will differ by the parameters listed above.

Placeboother