CI

At a glance

ClinicalIndex Comparison Record
Phase 4Completed· 141 enrolled
Drug / intervention
Dural puncture epidural (DPE) +3 moredrug
Likely dose
Dural puncture epidural (DPE) 2mcgfrom record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT03074695
NCT03074695Phase 4Completed

A Randomized Controlled Trial for Epidural Labor Analgesia: Comparison of Dural Puncture Epidural With Standard Labor Epidural Techniques

Duke University·interventional·Posted Mar 9, 2017·Updated Jun 1, 2022

In Brief

A Phase 4 clinical trial evaluating Dural puncture epidural (DPE) and Standard Epidural (EPL) for Morbid Obesity and Labor Pain. Completed, enrolled 141 participants across 1 site.

Detailed Summary

The primary purpose of this study is to determine differences in block quality between the "dural-puncture epidural" (DPE) and standard epidural (EPL) techniques for labor analgesia in the morbidly obese patient. The investigators hypothesize that when compared to the standard EPL, the DPE technique will improve block quality . Study participants will be randomized by computer-generated sequence to EPL or DPE arms, stratified by class of obesity (BMI 35-39.9 kg/m2, 40\< 50 kg/m2 and ≥ 50 kg/m2) and by parity (nulliparous versus multiparous). All patients will receive a neuraxial technique in the sitting position at L3/4 or L4/5 using loss of resistance to saline. In the DPE group, a 25-g Whitacre needle will be used to puncture the dura. In both groups, the epidural catheter will be threaded 5 cm in the epidural space with an initiation dose of 15 ml of ropivacaine 0.1% with fentanyl (2 mcg/ml) over 6 minutes as per standard practice. After the initial loading dose and epidural pump is started, the blinded investigator will enter the patient's room to start data collection (time 0). Data will be collected for the first 30 minutes of epidural placement at 3,6,9,12,15,18 21, and 30 minutes to detect the time to achieve target pain ≤ 1/10, then assessed at standardized times (ever 2 hour) until delivery. Breakthrough pain will be managed by a standardized protocol. Other data to be collected will include: catheter adjustments and replacements, physician top-ups, asymmetrical block, pain score, motor block, sensory level to ice, hypotension, total anesthetic dose required, and PCEA use. The primary outcome of this study is block quality defined by a composite of five components: (1) asymmetric block after 30 minutes of initiation, (2) top-up interventions, (3) catheter adjustments (4) failed catheter requiring replacement, and (5) failed epidural requiring general anesthesia or replacement neuraxial anesthesia for emergency cesarean section. Secondary outcomes include time to numeric pain rating scale ≤1, maternal adverse events (hypotension, fetal bradycardia, PDPH), motor block, duration of second stage of labor, total labor epidural time, total anesthetic dose required, PCEA use, and mode of delivery. There is no increased risk/safety issue with placing a dural puncture technique than with epidural for labor analgesia.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesUnited States
Collaborators--

Timeline

Phase 4CompletedFinished
2017201820192020202120222023202420252026
First PostedMar 9, 2017
Enrollment StartApr 1, 2017
Primary CompletionNov 6, 2020
TodayJul 2, 2026
Enrollment to primary: 3.6 yearsPosted 9.3 years ago

Interventions

Dural puncture epidural (DPE)procedure

Epidural with spinal needle placed to confirm cerebral spinal fluid (CSF) position. No intrathecal dosing

Standard Epidural (EPL)procedure

Standard epidural placement

Dural puncture epidural (DPE)drug

Epidural with spinal needle placed to confirm CSF position. No intrathecal dosing. Ropivacaine 0.1% and Fentanyl 2mcg/mL.

Standard Epidural (EPL)drug

Standard epidural placement. Ropivacaine 0.1% and Fentanyl 2mcg/mL.