CI

At a glance

ClinicalIndex Comparison Record
N/ACompleted· 175 enrolled
Drug / intervention
Linear Ultrasound to Measure Diaphragmatic Movement +2 moreother
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT03225508
NCT03225508N/ACompleted

A Novel Method to Measure Diaphragmatic Motion and Excursion

University Health Network, Toronto·observational·Posted Jul 21, 2017·Updated Jul 24, 2024

In Brief

An observational study evaluating Linear Ultrasound to Measure Diaphragmatic Movement, Curvilinear Ultrasound to Measure Diaphragmatic Movement, and 1 other intervention for Diaphragm; Movement and Examination of Diaphragm Movement Using Ultrasound. Completed, enrolled 175 participants across 1 site.

Detailed Summary

This study evaluates the movement of the diaphragm (which is the main muscle used for breathing). It will compare two ultrasound modalities: linear ultrasound versus curvilinear ultrasound, at measuring diaphragm motion. The proposed measurement method with linear ultrasound is novel, and will be compared against the established method with curvilinear ultrasound. The investigators hypothesize that the novel method will have several potential advantages, including: it may be easier to learn, quicker to perform, and have a lower failure rate.

Study Details

Study Typeobservational
Allocation--
Masking--
Primary Purpose--
CountriesCanada
Collaborators--

Timeline

N/ACompletedFinished
201820192020202120222023202420252026
First PostedJul 21, 2017
Enrollment StartJun 9, 2017
Primary CompletionMay 23, 2024
TodayJul 2, 2026
Enrollment to primary: 7.0 yearsPosted 8.9 years ago

Interventions

Linear Ultrasound to Measure Diaphragmatic Movementother

A linear 10-12 MHz ultrasound probe will be used to determine diaphragmatic excursion, by examining the zone of apposition. Diaphragmatic excursion will be measured from end inspiration to end expiration. The measurement will be repeated twice, and an average of the two will be taken. The distance between the two external skin markings, one at the end of full expiration and one at the end of full inspiration will indicate the excursion of the diaphragm.

Curvilinear Ultrasound to Measure Diaphragmatic Movementother

A curvilinear 2-5 MHz ultrasound probe will be used to determine diaphragmatic excursion, by examining the dome of the diaphragm. M-mode will be used to image the motion of the diaphragm from end inspiration to end expiration. The measurement will be repeated twice, and an average of the two will be taken.

Pulmonary function testsother

Bedside pulmonary function tests to measure forced vital capacity (FVC). The FVC measures the maximal volume of gas that can be expired as forcefully and rapidly as possible after a maximal inspiration to total lung capacity. This measurement will help determine if the patient has any obstructive or restrictive diseases of the airways. Three measurements will be taken.