CI

At a glance

ClinicalIndex Comparison Record
N/ACompleted· 26 enrolled
Drug / intervention
1RM Test +8 moreprocedure
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT03272737
NCT03272737N/ACompleted

Effect of Low Intensity Strength Training Combined With Moderate Blood Flow Restriction on Muscle Vasodilatation and Arterial Stiffness in Elders With Low Gait Velocity.

Hospital Israelita Albert Einstein·interventional·Posted Sep 6, 2017·Updated Feb 11, 2022

In Brief

A clinical study evaluating 1RM Test, Speed gait test, and 7 other interventions for Frail Elderly Syndrome. Completed, enrolled 26 participants across 1 site.

Detailed Summary

The purpose of the present study is to evaluate the acute and chronic effect of low intensity strength training with or without moderate blood flow restriction on muscle vasodilation and arterial stiffness in elders with low gait speed. In addition, the responses of prothrombotic factors in blood coagulation, the impact on heart rate and arterial pressure will be assessed.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesBrazil

Timeline

N/ACompletedFinished
201820192020202120222023202420252026
First PostedSep 6, 2017
Enrollment StartFeb 4, 2018
Primary CompletionJun 4, 2020
Study CompletionJan 4, 2022
TodayJul 2, 2026
Enrollment to primary: 2.3 yearsPosted 8.8 years ago

Interventions

1RM Testprocedure

The dynamic force of the lower limb muscles will be evaluated by the maximal repetition of knee extension and leg press exercise, according to the protocol presented in a previous study \[37\]. The elderly will perform a warm up consisting of 1 series with 10 unloaded repetitions. After the warm up, the mass to be lifted will be progressively increased until the maximum load that can be lifted is reached, with a maximum limit of 5 attempts and a 3 to 5 minutes interval between them. The test will be conducted by a physical education professional who will verbally encourage participants throughout these steps and perform the load adjustment at week 5 and 10 (Radaelli, 2014).

Speed gait testprocedure

To measure the gait speed of participants they will walk 4.6 metres and the time needed to cover this distance is measured. The mean of three attempts is recorded and divided by the distance. The participants included must achieve in the walking test an average of \< 0.,9 m/s (Guralnik, 1994).

Venous occlusion plethysmography protocoldevice

A mercury-filled silastic tube, connected to a low-pressure transducer and a plethysmograph (D.E. Hokanson), will be placed around the largest circumference of the calf region. One cuff will be placed around the ankle and another around the thigh. The ankle cuff will be inflated to a supra-systolic pressure 30 seconds before starting the measurements. At 15-second intervals, the cuff around the thigh will be inflated above the venous pressure for a period of seven to eight seconds. Increased tension in the silastic tube reflects an increase in leg volume and vasodilation. The signal of the muscle blood flow wave will be recorded on a polygraph and analysed every minute, averaging three records per minute. The protocol will be performed during 5 minutes of rest, 3 minutes isometric exercise and 2 minutes of recovery (Bahia, 2006).

Measurement of Arterial Stiffness - Pulse Wave Analysis and Velocitydevice

Arterial stiffness will be estimated from the carotid-femoral aortic pulse wave velocity \[33\]. Carotid-femoral aortic pulse waves will be recorded by tonometry (SphygmoCor, AtCor Medical, Australia). At the same time, an electrocardiogram will be obtained to calculate the wave transit time. Two distances will be measured: the recording point of the carotid artery and the sternal furcula (distance 1) and the sternal furcula and the recording point in the femoral artery (distance 2). The distance travelled by the pulse wave will be calculated as "distance 2" - "distance 1". The carotid-femoral aortic pulse wave velocity will be calculated as: carotid-femoral aortic pulse wave velocity = ¼ \* distance travelled by the pulse wave (m) / transit time(s).

Isometric handgrip exercise protocoldevice

In a supine position, the maximal voluntary handgrip force will be determined as the highest force in 3 consecutive attempts using a Jamar hydraulic palmar dynamometer (Asimow Engineering, CAL, USA). For activation of the central command, mechanoreceptors and muscular metaboreceptors the individual will perform, after 5 minutes of rest (baseline records), 3 minutes of exercise at 30% MVC. This manoeuvre isolates the activation of muscle metaboreceptors, observing the selective activation of these. After the isometric handgrip exercise, 2 minutes of recovery will be performed. Throughout the protocol muscle blood flow, blood pressure and heart rate will be recorded.

Vasodilatory capacitydevice

The vasodilatory capacity will be calculated as the percentage of increase of the diameter of the brachial artery and femoral post occlusion in relation to its basal values.

Basal blood flow and vasodilatory capacity - Flow mediated dilation (FMD)device

Images of the brachial artery will be recorded by a two-dimensional ultrasonography device with a spectral Doppler and linear transducer (Ultra-0122, Philips, The Netherlands).

Quality of Life EuroQol-5 Domainother

This questionnaire is used to estimate the quality of life in participants before and after the study.

Anthropometric Assessmentother

Anthropometric measurements will be made before and after the training program following the standardization of the International Society for Anthropometric Assessments. The body mass will be measured with an accuracy of 0.1 kg (Filizola). The stature will be obtained by means of the stadiometer with an accuracy of 0.5 cm. The BMI will be calculated as body mass divided by height squared. The circumference of the quadriceps will be measured with a tape measure (Seca) with a precision of 0.1 cm.