In Brief
A clinical study evaluating the Clarus Video System as a video stylet, the Clarus Video System as a lightwand, and 1 other intervention for Intubation, Intratracheal and 2 related conditions. Completed, enrolled 150 participants across 1 site.
Detailed Summary
During an emergency endotracheal intubation, rapid sequence induction intubation with cricoid pressure is frequently implemented to prevent aspiration pneumonia. When properly applied, cricoid pressure may not affect glottic view during endotracheal intubation with either a direct laryngoscope or a video laryngoscope. However, the application of cricoid pressure is likely to prolong the intubation time. Limited mouth opening or vulnerable teeth, which often accompany the patients requiring emergency intubation, are the two common factors to deter the intubators from using a laryngoscopic device. Besides, the blade of a laryngoscopic device is often too bulky for a narrow mouth opening, and the blade always bears a level force on upper incisors while the intubator is lifting epiglottis during intubation, which is liable to tooth fracture. In this prospective randomized study, the investigators compare the use of the Clarus Video System and that of direct laryngoscope (Macintosh Laryngoscope) in patients undergoing endotracheal intubation in simulated rapid sequence induction intubation for the primary goals of the first attempt success rate and intubation time.
Study Details
Timeline
Interventions
video-guided intubation
The endotracheal tube will be initially guided into larynx in the dimly lit operating room by a bright glow moving in the anterior soft tissue of the neck and finally by the image of the trachea rings on the video screen.
Macintosh laryngoscope size 3