CI

At a glance

ClinicalIndex Comparison Record
N/ACompleted· 140 enrolled
Drug / intervention
Investigational device: Biosure Regenesorb Interference Screw +1 moredevice
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT04012567
NCT04012567N/ACompleted

A Prospective, Multi-center, Randomized Clinical Study to Evaluate the Safety and Effectiveness of Biosure Regenesorb Interference Screw in Arthroscopic Reconstruction of Cruciate Ligaments in Chinese Patients

Smith & Nephew, Inc.·interventional·Posted Jul 9, 2019·Updated Mar 25, 2025

In Brief

A clinical study evaluating Investigational device: Biosure Regenesorb Interference Screw and Control device: BIOSURE HA Interference Screw for Cruciate Ligament Reconstruction and Knee. Completed, enrolled 140 participants across 4 sites.

Detailed Summary

The objective of this study is to compare the safety and effectiveness of Biosure Regenesorb Interference Screw versus BIOSURE HA Interference Screw (control device) in patients requiring reconstruction of cruciate ligaments of the knee. The trial results will be used for registration of Biosure Regenesorb Interference Screw in China. The primary efficacy endpoint of this study is Lysholm score at 12 months after operation. The non-inferiority testing is performed for efficiency of primary efficacy endpoint, and the test hypothesis is as follows: Invalid hypothesis: H0: μ1-μ2 ≤-δ Alternative hypothesis: H1: μ1-μ2 \> -δ, where, μ1 and μ2 are the Lysholm scores in the investigational group and control group, respectively. δ is a non-inferiority critical value.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesChina
Collaborators--

Timeline

N/ACompletedFinished
2020202120222023202420252026
First PostedJul 9, 2019
Enrollment StartDec 17, 2019
Primary CompletionSep 11, 2021
Study CompletionNov 9, 2022
TodayJul 2, 2026
Enrollment to primary: 1.7 yearsPosted 7.0 years ago

Interventions

Investigational device: Biosure Regenesorb Interference Screwdevice

The Biosure Regenesorb Interference Screw, an absorbable screw designed with an open structure and made of biocomposite material made of PLGA, β-TCP and calcium sulfate, is used to fix ligaments, tendons, soft tissues or bone-tendon-bone grafts in knee surgery. Its open structural design enables rapid bone ingrowth to make the screw integrated with bone tissues so as to promote healing.

Control device: BIOSURE HA Interference Screwdevice

BIOSURE HA Interference Screws and Drivers are designed for durability and reduced screw breakage. Both the screws and driver have been enhanced to allow screws to fully seat on the driver all the way to the tip of the screw, helping stress distribution and force transfer. The screw design also incorporates a consistent wall thickness throughout the length of the screw for added durability and features a tapered body for ideal ease of insertion.