CI

At a glance

ClinicalIndex Comparison Record
N/ACompleted· 133 enrolled
Drug / intervention
Non-invasive ventilationdevice
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT04323397
NCT04323397N/ACompleted

Nasal High Frequency Oscillatory Versus Synchronized Intermittent Positive Pressure Ventilation in Neonate Following Extubation: Randomized Controlled Crossover Study

Prince of Songkla University·interventional·Posted Mar 26, 2020·Updated Mar 3, 2025

In Brief

A clinical study evaluating Non-invasive ventilation for High-Frequency Ventilation and 3 related conditions. Completed, enrolled 133 participants across 1 site.

Detailed Summary

Mechanical ventilation was introduced to treat respiratory failure in preterm infants or sick neonates then improvements in survival (1,2). However, the complications from short or long term use of ventilation can result in unintended harm or burden (e.g., air leak syndrome, pneumonia, bronchopulmonary dysplasia, neurological injury, retinopathy of prematurity) (3,4). To reduce these risks, clinicians should aggressive extubated neonates as early as possible. Respiratory (focus on blood gas as well as partial pressure CO2 \[pCO2\]) or extubation (focus on clinical condition as well as reintubation) failure was worrisome in pediatrician and parents if the neonate was reintubated owing to complete recovery of lung disease or inadequate respiratory drive. Non-invasive ventilation (NIV) was supported for primary respiratory support (initial mode before endotracheal intubation) or post-extubation. Nasal continuous positive airway pressure (nCPAP) was familiar to NIV mode in neonatal respiratory support. Nowadays, the new NIV modalities are nasal intermittent synchronized positive pressure ventilation (nSIPPV) and nasal high frequency oscillation (nHFO). To increase the likelihood of nCPAP success, other new modalities of NIV may be interesting. From theory, nSIPPV and nHFO combines peak inspiratory pressure (PIP) with synchrony and high-frequency oscillations without synchrony above CPAP, respectively. From meta-analysis, nSIPPV and nHFO were statistically significant superior than nCPAP both respiratory and extubation failure in neonate (5,6). The aim of our study was to investigate the efficacy of nHFOV and nSIPPV for CO2 clearance and reintubation rate after extubated neonates. The investigators hypothesized that nHFOV mode would improve CO2 clearance better than nSIPPV mode.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesThailand
Collaborators--

Timeline

N/ACompletedFinished
202120222023202420252026
First PostedMar 26, 2020
Enrollment StartJul 1, 2020
Primary CompletionJun 30, 2022
Study CompletionAug 1, 2022
TodayJul 2, 2026
Enrollment to primary: 2.0 yearsPosted 6.3 years ago

Interventions

Non-invasive ventilationdevice

Intervention nasal high frequency oscillatory ventilation (nHFOV) and nasal synchronized intermittent positive pressure ventilation (nSIPPV) were generated by neonatal ventilators (SLE6000 infant ventilators, United Kingdom) using bi-nasal prongs (RAM cannula, NEOTECH®, USA) or the nasal mask of the same type for both ventilation modes. The size of the prongs was determined by the infant's weight. The largest possible prongs were used, with a snug fit to avoid leakage. Pacifier for preterm and term neonate (Jollypop™, USA) was taken to avoid leakage from the mouth. The disposable ventilator circuit (Fisher \& Paykel RT268™, Evaqua Dual Limb Infant Breathing Circuit Kit with Evaqua 2 Technology and Pressure Line, Flow \> 4L/min, New Zealand) was used. The initial NIV setting was (7) described in arm description. (above)