CI

At a glance

ClinicalIndex Comparison Record
N/ACompleted· 10 enrolled
Drug / intervention
Tidal volume measured by spirometer and DIBH surface from CT imagedevice
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT04686500
NCT04686500N/ACompleted

VisionRT-based Deep Inspiration Breath-hold (DIBH) Respiratory Motion Management Strategy, A Pilot Study for Thoracic and Abdominal Tumors Stereotactic Body Radiotherapy

University of Texas Southwestern Medical Center·interventional·Posted Dec 28, 2020·Updated Nov 25, 2024

In Brief

A clinical study evaluating Tidal volume measured by spirometer and DIBH surface from CT image for Thoracic Cancer and Abdominal Cancer. Completed, enrolled 10 participants across 1 site.

Detailed Summary

A more recent competing technology for implementing the DIBH technique is real-time surface photogrammetry using the AlignRT system (Vision RT Ltd., London, UK). AlignRT system use non-ionization near infrared light to track patient surface motion. The system has one projector projecting near infrared optical pattern on patient surface. The optical pattern is imaged by optical cameras (two per pod) at \~25 Hz. The user selects a region-of-interest (ROI) on the surface and the software calculates and displays the real-time position in six degrees (3 translations and 3 rotations) in real-time. Once the patient has matched the pre-determined DIBH position (within threshold accuracy), the radiation beam is enabled to be turned on for treatment.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesUnited States
CollaboratorsVision RT Limited

Timeline

N/ACompletedFinished
20192020202120222023202420252026
First PostedDec 28, 2020
Enrollment StartMar 1, 2019
Primary CompletionJul 20, 2021
Study CompletionJun 21, 2023
TodayJul 2, 2026
Enrollment to primary: 2.4 yearsPosted 5.5 years ago

Interventions

Tidal volume measured by spirometer and DIBH surface from CT imagedevice

The SOC DIBH CT scan will be transferred to Eclipse treatment planning system for treatment planning. Tidal volume measured by spirometer and DIBH surface from CT image will be used as a reference surface for patient treatment initial setup. CBCT will be acquired before each fractional treatment for the patient alignment before beam delivery.