A Randomized Control Trial to Compare the Effects Between Wearable Robotic System and Robotic Mirror Therapy in Patients With Spastic Hemiplegia Post Botulinum Toxin Injection: Neurophysiological and Behavior Outcomes
In Brief
A clinical study evaluating BoNT-A injections, Robotic therapy (RT), and 2 other interventions for Hemiplegia, Spastic and Spastic. Completed, enrolled 31 participants across 1 site.
Detailed Summary
The purpose of this project is to examine and compare the immediate and long-term effects of combined Botulinum toxin type A(BoNT-A) injection with wearable robotic hand system (RT) and Robotic mirror therapy (RMT) in patients with spastic hemiplegic stroke.
Study Details
Timeline
Interventions
Botox brand BoNT-A Purified Neurotoxin Complex, (Allergan Pharmaceuticals, Irvine, CA) will be prepared by diluting lyophilized toxin with 0.9% saline to a concentration of 33-100 U/ml. depending on the size of the target muscle. Location of the targeted muscle will be confirmed by using echo guide. The total dose range is 200 units to 500 units. The dose range of each target muscle is as below: 20 and 75 units for flexor carpi ulnaris and flexor carpi radials; 12.5-35 units per fascicle in the flexor digitorum sublimis and flexor digitorum profundus (maximum dose: 120 units for each of these muscles); 10-35 units in the flexor pollicis longus; 25-100 units in the brachioradial ; 50-200 units in the biceps brachii; and 25-75 units in the pronator teres
A wearable robotic hand system will be used in this study. The robotic hand system consisted with a wearable exoskeletal hand, sensor glove, and a control box. On the exoskeletal hand, there are five actuators on each of finger structure that can provide external power to bring individual finger moving. The sensor glove has five sensors that can detect the finger's posture during movement and then manipulates exoskeletal hand via the control box. The patient's unaffected hand wears the sensor glove, the affected hand wears the wearable exoskeleton hand, and the unaffected hand does the certain transitive and intransitive tasks as the mirror group, and then makes the affected hand do the same movements driven by the exoskeleton robotic hand.
Wearable robotic hand system and mirror system will be used in this group.. The patients in the group will wear the robotic hand to do the mirror therapy. The patient's unaffected hand wears the sensor glove, the affected hand wears the wearable exoskeletal hand, a mirror box with a mirror will be placed in the patient 's midsagittal plane beside the unaffected hand to block his or her view of the affected hand. The patient's unaffected hand does the certain transitive and intransitive tasks and the patient will be instructed to look at the reflection of the unaffected hand in the mirror as if it is the affected hand (the visual input). At the same time the affected hand will be passively moved by the exoskeleton robotic hand which is under the .control of the unaffected hand.
After either 45 minutes of RT or RMT, all participants receive 15 minutes of training in functional tasks. The functional tasks included taking up and holding bowl or using eating utensils , bringing a cup for drinking, drying sucks by clips, open ing or closing door , turning on or off the light, cleaning the table or window and so on . The functional tasks training will be bases on the needs and ability of patients.