CI

At a glance

ClinicalIndex Comparison Record
N/ACompleted· 80 enrolled
Drug / intervention
Use of Insulclock system, both Insulclock device and Insulclock 360 app. +1 moredevice
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT04847778
NCT04847778N/ACompleted

Randomized Clinical Trial to Assess the Efficacy of the System Insulclock® 360 for Insulin Treatment Management in Type 1 Diabetes Patients With Insufficient Glycemic Control

Hospital General de Segovia·interventional·Posted Apr 19, 2021·Updated Mar 11, 2022

In Brief

A clinical study evaluating Use of Insulclock system, both Insulclock device and Insulclock 360 app. and Use of Insulclock system, both Insulclock device and Insulclock app on masked mode. for Diabetes Mellitus, Type 1. Completed, enrolled 80 participants across 4 sites.

Detailed Summary

Insulclock® is a small electronic device developed to facilitate the optimal administration of insulin. This device works as an add-on module of commercially available insulin pens and monitors the date, time and dose of injections, the type of insulin injected, the duration of injections and insulin temperature. The Insulclock 360 app allows automatic data logging, report generation and reminder setting, among other functions. In this study, we pretend to show the clinical impact of Insulclock system, both device and mobile application, on glycemic indices, treatment compliance, and quality of life in patients with persistent poorly controlled T1DM. Material and methods: Randomized open-label multicenter controlled trial to evaluate glycemic control, the number of missed and delayed insulin doses, and quality of life after seven weeks of Insulclock 360 use in participants with uncontrolled DM1. We will also compare these results between patients with or without receiving system reminders and alerts. This study aims to assess the effect of Insulclock on glycemic control, treatment adherence, and quality of life. As a secondary objective, we will compare the study outcomes between participants in the Active and Masked Insulclock groups (i.e., with or without receiving alerts and reminders and accessing the app). To assess glycemic control, we will measure HbA1C and glycemic indices. Glycemic variability indices will be monitored with the FreeStyle Libre™ and included glucose coefficient of variation (CV), standard deviation (SD), time in range (TIR), time above range (TAR), and time below range (TBR). Mean glucose levels will be obtained from 48-h time intervals with the FreeStyle Libre. A late meal bolus (mistimed) will be considered when Insulclock detects the injection at least 30 minutes after the CGM rise. To identify meal glucose excursions, we will use the Glucose Rate Increase Detector (GRID) algorithm, which estimates the rate of change (ROC) of glucose from CGM data. Participants will complete the ITSQ and the DTSQ, which are validated questionnaires to assess the diabetes treatment satisfaction.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesSpain
CollaboratorsInsulcloud S.L.

Timeline

N/ACompletedFinished
20222023202420252026
First PostedApr 19, 2021
Enrollment StartMar 1, 2021
Primary CompletionJun 30, 2021
Study CompletionJul 31, 2021
TodayJul 2, 2026
Enrollment to primary: 4 monthsPosted 5.2 years ago

Interventions

Use of Insulclock system, both Insulclock device and Insulclock 360 app.device

Visit 5, during week 4. Randomization will be applied: Active group will use all functionalities of Insulclock 360. They will have reminders, all their information and statistics at the disposition of the patient and healthcare providers, they have the assistance if desired of an ally or caregiver, a bolus calculator and the rest of functionalities described in the protocol.

Use of Insulclock system, both Insulclock device and Insulclock app on masked mode.device