CI

At a glance

ClinicalIndex Comparison Record
N/ACompleted· 44 enrolled
Drug / intervention
Russian current 10% +3 moreother
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT05061056
NCT05061056N/ACompleted

Neuromuscular Electrical Stimulation: Comparison of Carrier Frequencies, Bursts Durations and Duty Cycles in the Generation of Evoked Torque, Sensory Discomfort, Muscle Fatigue and Peripheral Oxygen Extraction

University of Brasilia·interventional·Posted Sep 29, 2021·Updated May 24, 2023

In Brief

A clinical study evaluating Russian current 10%, Russian current 20%, and 2 other interventions for Fatigue. Completed, enrolled 44 participants across 1 site.

Detailed Summary

Neuromuscular Electrical Stimulation (NMES) can minimize muscle atrophy, complications related to muscle disuse and improved neuromuscular performance. However, it is still unclear the influence of specific physical parameters, including carrier frequency, burst duration, and duty cycle regarding the greater generation of evoked torque, sensory discomfort, muscle fatigue, and peripheral oxygen extraction. Thus, the aim of this study is to compare the effects of different NMES protocols applied to the triceps surae muscle for evoked torque, muscle fatigue, sensory discomfort, and peripheral oxygen extraction in healthy individuals. This is a crossover, experimental, randomized, double-blind trial composed of apparently healthy participants. All NMES protocols will be tested on the same individual with randomization of the sequence of intervention protocols. There will be a total of 6 encounters with seven days between them. Session 1 will evaluate the anthropometric measures, the maximum intensity for each intervention protocol, and the sequence of intervention protocols for each individual will be randomized. Sessions 2, 3, 4, and 5 will be composed equally with the assessment of the maximum voluntary and evoked joint torque of the triceps surae muscle through the isokinetic dynamometer, evaluation of muscle fatigue through the H-reflex, M-wave, fatigue index, time-torque-integral, and recruitment curve, evaluation of peripheral oxygen extraction through NIRS (Near Infrared Spectroscopy), electromyographic signals to assessed the RMS (root mean square) and the median frequency, evaluation of the level of sensory discomfort through the Visual Analog Pain Scale and finally by the NMES protocol. The 6th session will be the replication of the 2nd session of each individual. The EENM protocols will be as follows: CR10% (Russian Current with 2500 Hz, modulated in bursts of 50 Hz, 200 µs and 10% duty cycle - 2 ms bursts and 18 ms interbusrts), CR20% (Russian Current with 2500 Hz, modulated in bursts of 50 Hz, 200 µs and 20% of duty cycle - 4 ms bursts and 16 ms interbusrts), CA10% (Aussie current with 1000 Hz, modulated in bursts of 50 Hz, 500 µs and 10% duty cycle - 2 ms of bursts and 18 ms interbusrts), CA20% (Aussie current with 1000 Hz, modulated in bursts of 50 Hz, 500 µs and 20% of duty cycle - 4 ms of bursts and 16 ms interbusrts) all protocols will be performed on the triceps surae muscle.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
ConditionsFatigue
CountriesBrazil
Collaborators--

Timeline

N/ACompletedFinished
20222023202420252026
First PostedSep 29, 2021
Enrollment StartNov 2, 2021
Primary CompletionMay 22, 2022
TodayJul 2, 2026
Enrollment to primary: 7 monthsPosted 4.8 years ago

Interventions

Russian current 10%other

Russian current with 2500 Hz, modulated in bursts of 50 Hz, 200 µs and 10% duty cycle - 2 ms bursts and 18 ms interbusrts

Russian current 20%other

Russian current with 2500 Hz, modulated in bursts of 50 Hz, 200 µs and 20% duty cycle - 4 ms bursts and 16 ms interbusrts

Aussie current 10%other

Aussie current with 1000 Hz, modulated in bursts of 50 Hz, 500 µs and 10% duty cycle - 2 ms bursts and 18 ms interbusrts

Aussie current 20%other

Aussie current with 1000 Hz, modulated in bursts of 50 Hz, 500 µs and 20% duty cycle - 4 ms bursts and 16 ms interbusrts