CI

At a glance

ClinicalIndex Comparison Record
N/ACompleted· 323 enrolled
Drug / intervention
Theranova 400 Dialyzer +1 moredevice
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT05309291
NCT05309291N/ACompleted

A Randomized, Open-label, Controlled, Parallel, Multicenter Study in Kidney Failure Patients on Hemodialysis Comparing the Theranova Dialyzer to Hemodiafiltration

Vantive Health LLC·interventional·Posted Apr 4, 2022·Updated Jul 14, 2025

In Brief

A clinical study evaluating Theranova 400 Dialyzer and FX 800 Dialyzer for Chronic Kidney Failure and Acute Kidney Failure. Completed, enrolled 323 participants across 10 sites.

Detailed Summary

Traditional hemodialysis (HD) therapy is very effective in clearing urea and smaller middle molecules, but is limited in clearing larger middle molecules. These accumulated large middle-molecular-weight uremic toxins may cause and aggravate inflammation, atherosclerosis and calcification, which can indirectly lead to the death of patients. Studies have shown that, compared to conventional high-flux HD (HF-HD), hemodiafiltration (HDF) that combines diffusion and convection can reduce the all-cause mortality. Compared to the conventional HF-HD, HDF can more effectively clear larger molecular toxins in one session, which may be related to the better clearance effect of HDF on middle-molecular-weight toxins Theranova's innovative Medium Cut-Off® membranes has high permeability and selectivity to uremic toxins (clearance of a molecular weight of up to 45 kDa) and can retain essential proteins, to maintain patient's albumin level during the HD treatment\[9\]. Its unique membrane and high cut-off characteristics expand the clearance range beyond those of flux membrane dialyzers. Theranova 400 can be widely used in most blood purification centers under conventional HD equipment and treatment modes, with the effect similar to HDF This study is to demonstrate non-inferiority of the Theranova 400 Dialyzer in HD mode (hereinafter referred to as Theranova 400) compared to HDF, using FX 800 in HDF mode (hereinafter referred to as FX 800).

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesChina

Timeline

N/ACompletedFinished
2023202420252026
First PostedApr 4, 2022
Enrollment StartJun 22, 2022
Primary CompletionJul 6, 2023
TodayJul 2, 2026
Enrollment to primary: 1.0 yearsPosted 4.2 years ago

Interventions

Theranova 400 Dialyzerdevice

Dialysis performed in HD mode.

FX 800 Dialyzerdevice

Dialysis performed in HDF mode.