Automated Oxygen Control for Preterm Infants On Continuous Positive Airway Pressure (CPAP): Phase 1/2 Trial In Southwest Nigeria

Murdoch Childrens Research Institute·interventional·Posted Aug 19, 2022·Updated Nov 13, 2023

In Brief

A clinical study evaluating OxyMate and Manual oxygen control for Neonatal Respiratory Distress Related Conditions and 3 related conditions. Completed, enrolled 49 participants across 2 sites.

Detailed Summary

One in ten babies are born preterm (\<37 weeks gestation) globally. Complications of prematurity are the leading cause of death in children under 5 years, with the highest mortality rate in Sub-Saharan Africa (SSA). Low flow oxygen, and respiratory support - where an oxygen/air mixture is delivered under pressure - are life saving therapies for these babies. Bubble Continuous Positive Airway Pressure (bCPAP) is the mainstay of neonatal respiratory support in SSA. Oxygen in excess can damage the immature eyes (Retinopathy of Prematurity \[ROP\]) and lungs (Chronic Lung Disease) of preterm babies. Historically, in well-resourced settings, excessive oxygen administration to newborns has been associated with 'epidemics' of ROP associated blindness. Today, with increasing survival of preterm babies in SSA, and increasing access to oxygen and bCPAP, there are concerns about an emerging epidemic of ROP. Manually adjusting the amount of oxygen provided to an infant on bCPAP is difficult, and fearing the risks of hypoxaemia (low oxygen levels) busy health workers often accept hyperoxaemia (excessive oxygen levels). Some well resourced neonatal intensive care units globally have adopted Automated Oxygen Control (AOC), where a computer uses a baby's oxygen saturation by pulse oximetry (SpO2) to frequently adjust how much oxygen is provided, targetting a safe SpO2 range. This technology has never been tested in SSA, or partnered with bCPAP devices that would be more appropriate for SSA. This study aims to compare AOC coupled with a low cost and robust bCPAP device (Diamedica Baby CPAP) - OxyMate - with manual control of oxygen for preterm babies on bCPAP in two hospitals in south west Nigeria. The hypothesis is that OxyMate can significantly and safely increase the proportion of time preterm infants on bCPAP spend in safe oxygen saturation levels.

Study Details

Timeline

N/ACompletedFinished
2023202420252026
First PostedAug 19, 2022
Enrollment StartSep 13, 2022
Primary CompletionSep 29, 2023
TodayJul 2, 2026
Enrollment to primary: 1.0 yearsPosted 3.9 years ago

Interventions

OxyMatedevice

Automated Oxygen Control algorithm (VDL 1.1) coupled with Diamedica Baby CPAP device

Manual oxygen controlother

Guidelines and training in FiO2 titration to achieve a target range of SpO2. Health workers instructed in responding to continuous pulse oximetry readings and alarms