CI

At a glance

ClinicalIndex Comparison Record
Phase 2Completed· 15 enrolled
Drug / intervention
PLIFUS +2 moredevice
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT05643196
NCT05643196Phase 2Completed

A Sham-Controlled Pilot Trial of Focused Ultrasound Modulation of the Globus Pallidus Interna in Schizophrenia

NYU Langone Health·interventional·Posted Dec 8, 2022·Updated May 30, 2025

In Brief

A Phase 2 clinical trial evaluating PLIFUS, Sham PLIFUS, and 1 other intervention for Schizophrenia and Schizophrenia Schizoaffective. Completed, enrolled 15 participants across 2 sites.

Detailed Summary

This is a single-site, phase 2, sham-controlled random-order cross-over pilot trial of PLIFUS targeting the right GPi in individuals with schizophrenia. Twelve individuals with schizophrenia who report continuous hallucinations or delusions of mild or greater severity will receive one session of PLIFUS and one session of sham PLIFUS in random order, one week apart. If no effect of PLIFUS is detected on measures of functional connectivity or psychotic symptoms in the first four completers, the trial will be changed to 3 sessions of PLIFUS or sham administered over 5 days.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesUnited States

Timeline

Phase 2CompletedFinished
2023202420252026
First PostedDec 8, 2022
Enrollment StartApr 6, 2023
Primary CompletionMar 25, 2024
Study CompletionApr 1, 2024
TodayJul 2, 2026
Enrollment to primary: 12 monthsPosted 3.6 years ago

Interventions

PLIFUSdevice

The Sonicator-1000 system will non-invasively deliver ultrasound sonications transcranially that selectively target specific areas of the brain using a neuronavigation system and the participant's MRI brain scan. The sonication parameters follow FDA and Electrotechnical Technical Commission regulation standards for diagnostic and therapeutic ultrasound.

Sham PLIFUSdevice

Sham PLIFUS treatment delivers noise and patient experience that is identical to PLIFUS with Sonicator-1000 system.

MRIdevice