CI

At a glance

ClinicalIndex Comparison Record
N/ACompleted· 70 enrolled
Drug / intervention
Silk 0-0 suture covered by chlorhexidine gluconate dressing +1 moreprocedure
Likely dose
Not stated in record
Structured eligibility isn't available for this trial yet — see the full criteria in the Eligibility tab below.

Standardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.

Search/NCT06589284
NCT06589284N/ACompleted

Skin Glue Versus Suture for Securing Radial Arterial Lines

CHRISTUS Health·interventional·Posted Sep 19, 2024·Updated Sep 19, 2024

In Brief

A clinical study evaluating Silk 0-0 suture covered by chlorhexidine gluconate dressing and 2-octyl cyanoacrylate covered by chlorhexidine gluconate dressing for Arterial Catheters and Catheter Related Complication. Completed, enrolled 70 participants across 1 site.

Detailed Summary

Prior investigators have evaluated the use of 2-octyl cyanoacrylate (glue) as a method to secure a variety of venous catheters including central/peripheral lines. There is a paucity of research evaluating the use of glue for arterial catheters. The investigators conducted a pilot study to test the null hypothesis that there would be no difference in failure rates between radial arterial lines (r-a-line) secured with glue vs. suture.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesUnited States
Collaborators--

Timeline

N/ACompletedFinished
202420252026
First PostedSep 19, 2024
Enrollment StartJun 15, 2023
Primary CompletionJun 14, 2024
TodayJul 2, 2026
Enrollment to primary: 12 monthsPosted 1.8 years ago

Interventions

Silk 0-0 suture covered by chlorhexidine gluconate dressingprocedure

The specific intervention will be securing radial arterial catheters with either skin adhesive or suture material. Both are largely accepted to be standard of care but to date there is a paucity of literature directly comparing the two for radial arterial lines. During the intervention the placement of radial arterial catheters will be done via standard sterile procedure and using seldinger technique which involves using a guidewire to slide the arterial catheter into the radial artery. After the catheter is placed, it will be secure with either straight suture with a cutting needle or via skin adhesive. Following securement, the area will be cleaned and a Tegaderm dressing with biopatch will be placed over the catheter. Data will be collected immediately after the procedure including length of procedure and complications as well as via chart review to determine the length of time the catheter was in place and evidence of premature failure.

2-octyl cyanoacrylate covered by chlorhexidine gluconate dressingprocedure

The specific intervention will be securing radial arterial catheters with either skin adhesive or suture material. Both are largely accepted to be standard of care but to date there is a paucity of literature directly comparing the two for radial arterial lines. During the intervention the placement of radial arterial catheters will be done via standard sterile procedure and using seldinger technique which involves using a guidewire to slide the arterial catheter into the radial artery. After the catheter is placed, it will be secure with either straight suture with a cutting needle or via skin adhesive. Following securement, the area will be cleaned and a Tegaderm dressing with biopatch will be placed over the catheter. Data will be collected immediately after the procedure including length of procedure and complications as well as via chart review to determine the length of time the catheter was in place and evidence of premature failure.