Feasibility Of Measuring Volume of Inspiration Via Non-Invasive Motion Sensors

National Institutes of Health Clinical Center (CC)·interventional·Posted Sep 24, 2024·Updated Feb 2, 2026

In Brief

A clinical study evaluating Motion Sensor and Incentive Spirometer for Postoperative Pulmonary Complications (PPCs). Completed, enrolled 30 participants across 1 site.

Detailed Summary

Background: Lung problems develop in up to 20% of people after they have surgery. While under general anesthesia, people breathe slower and draw in less air. They may have difficulty returning to normal deep breathing as they recover. Some may develop life-threatening complications. An approved device called an incentive spirometer is used to help measure and improve a person's breathing after surgery. Researchers want to find out if a motion sensor placed on the chest can also measure the volume of air a person inhales as they breathe. Objective: To determine if a motion sensor on the chest can measure the volume of air a person breathes. Eligibility: Healthy adults aged 18 years and older. Design: * Participants will have one clinic visit. The visit will last 10 to 30 minutes. * They will fill out a form with their age, sex, height, and weight. * A small, plastic motion sensor will be taped to their chest on one or both sides. * Participants will breathe through a tube attached to an incentive spirometer. They will take 18 breaths of different volumes, both deep and shallow. * Researchers will use the data collected from the motion sensors to measure how the chest moves at different levels of breathing. The motion sensor data will be used to create a software program that converts chest wall motion to the volume of air inhaled for a given breath in real time.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesUnited States
Collaborators--

Timeline

N/ACompletedFinished
20252026
First PostedSep 24, 2024
Enrollment StartJan 21, 2025
Primary CompletionApr 4, 2025
TodayJul 2, 2026
Enrollment to primary: 2 monthsPosted 1.8 years ago

Interventions

Motion Sensordevice

The motion sensor is the 10-axis Bluetooth Gyro Inclinometer by Wit Motion and is marketed for rehabilitation exercises, workplace injury prevention, patient care, and healthy short-range wireless motion measurements.

Incentive Spirometerdevice

A device that measures the volume of the air inhaled into the lungs during inspiration.