Comparison of Three Point-of-care Ultrasound Techniques to Confirm Endotracheal Tube Placement: a Randomized Clinical Trial

Marmara University Pendik Training and Research Hospital·interventional·Posted Oct 24, 2024·Updated May 27, 2026

In Brief

A clinical study evaluating Tracheal Ultrasound, Lung Ultrasound, and 1 other intervention for Intubation; Difficult or Failed. Completed, enrolled 200 participants across 1 site.

Detailed Summary

This study is a single-center, randomized clinical trial conducted in an emergency department on intubated patients with rapid sequence intubation. Two sonographers will independently verify the accuracy of the intubation site using the assigned intubation method (tracheal, lung-sliding, or diaphragm) according to the randomization sequence. Each sonographer will be blinded to the other verification methods (physical examination, end-tidal carbon dioxide) being used. The study's primary objective is to compare the diagnostic accuracy of different intubation techniques.

Study Details

Study Typeinterventional
Allocation--
Masking--
Primary Purpose--
CountriesTurkey (Türkiye)
Collaborators--

Timeline

N/ACompletedFinished
20252026
First PostedOct 24, 2024
Enrollment StartJun 1, 2024
Primary CompletionJun 19, 2025
TodayJul 2, 2026
Enrollment to primary: 1.1 yearsPosted 1.7 years ago

Interventions

Tracheal Ultrasoundother

In the clinic, one of the routinely used ultrasound machines, either the HM70 EVO Linear Probe (5-12 MHz) or the eSaote MyLab Seven Linear Probe (3-13 MHz), will be selected based on suitability for the procedure at the time. A linear transducer will be placed perpendicular to the trachea at the level of the cricoid membrane. During ETI, visualization of the ETT moving within the trachea, specifically behind the cricothyroid membrane, indicates successful intubation. In contrast, if the ETT is mistakenly placed in the esophagus, a double-lumen appearance lateral to the trachea, created by the ETT within the esophagus, suggests esophageal intubation.

Lung Ultrasoundother

In the clinic, one of the routinely used ultrasound machines, either the HM70 EVO Linear Probe (5-12 MHz) or the eSaote MyLab Seven Linear Probe (3-13 MHz), will be selected based on suitability for the procedure at the time. Following ETI, the presence of lung sliding will be evaluated using ultrasound with the aid of a linear probe. The transducer will be placed bilaterally along the mid-clavicular line, between the second and fifth intercostal spaces, in a coronal orientation. After the ETT is placed and ventilation is initiated, the movement of the visceral and parietal pleura will be assessed. The presence of sliding motion between these pleural layers during ventilation indicates successful intubation, whereas the absence of this movement suggests a failed intubation.

Diaphragm Ultrasoundother

In the clinic, one of the routinely used ultrasound machines, either the HM70 EVO Curvilinear Probe (2-8 MHz) or the eSaote MyLab Seven Curvilinear Probe (1-8 MHz), will be selected based on suitability for the procedure at the time. Using a curvilinear transducer, the probe will be placed along the mid-axillary line, approximately at the seventh to ninth intercostal spaces, in a coronal orientation. The movement of the diaphragm during ventilation will be assessed over the spleen and liver. Diaphragmatic motion during ventilation indicates successful ETI, while the absence of bilateral diaphragmatic movement suggests esophageal intubation. If diaphragmatic movement is only observed on one side, it is indicative of endobronchial intubation.