At a glance
ClinicalIndex Comparison RecordStandardized by ClinicalIndex from the ClinicalTrials.gov record · verify against the source.
Revitalize Cognition: A Proof of Concept Study Using Transcranial Near Infrared Stimulation in Older Adults
In Brief
A clinical study evaluating Active NIR-PBM (MedX 1116, MCT502) and Sham NIR-PBM (MedX 1116, MCT502) for Parkinson Disease. Completed, enrolled 23 participants across 1 site.
Detailed Summary
The overall goal of this pilot, proof of concept study is to test a novel, relatively low cost, low risk and potentially high impact intervention for cognitive and motor symptoms associated with idiopathic Parkinson Disease. The intervention involves transcranial delivery of near infrared (NIR) light, aka as photobiomodulation (PBM). This pilot randomized controlled trial will examine whether NIR stimulation influences cognitive, mood, and motor symptoms in Parkinson patients relative to a sham treated group. The goal is to determine effect sizes for a potentially larger study. Aims 1-3 of this study (Older Adult Specific) is registered separately under NCT02582593
Study Details
Timeline
Interventions
Near infrared light was delivered using two MedX Rehab Console systems (MedX Health, 1116). Each MedX console included a control unit and 3 superluminous light emitting diode (LED) clusters. Each LED cluster (3MedX MCT502) consisted of 52 near infrared diodes and 9 visible red diodes. The 9 red diodes were deactivated. The energy delivered by each cluster was 1 joule \[J\]/cm2 in 45 sec at treatment wavelength of 870 nm per each 20 min. The LED cluster has an irradiance of 22.2 mW/cm2, treats an area of 22.48 cm2, with an energy density of 26.64/cm2 per cluster (total energy of 599J/cluster). During each session, the 6 clusters were arrayed on the scalp in 2 configurations, 20 minutes per array. Each configuration targeted 6 transcranial sites, guided by the 10-20 system, for a total of 12 sites during the 40-min session. Total energy delivered was 599J/cluster X 12 sites = 7188J. Dosing was based on a pilot study. This intervention was given 3 times/week for 2 weeks.
The MedX sham intervention device is identical in all respects to the active device, except that the MedX console and diode clusters were modified to NOT deliver NIR light when turned on. The sham MedX devices were modified to deliver 'warmth', similar to that of the active devices. As with the active condition, a total of six sham interventions were given over a 2-week period, following the identical procedures described in the active condition.